The patented CVD application process means the coating can be precision applied to all surfaces of mesh tubes with outside diameters from 1.5”- 6”. The minimum mesh micron rating size is 175 μm; excellent for new and remedial well sand screens, and challenging filtration applications.
Hardide-T Mesh can be applied in a range of thickness from 15 – 40 μm (0.0006”-0.0016”) depending on the design and function of the mesh. The minimum coating hardness for mesh is 1250 Hv (58 HRc).
The coating has completed a rigorous test program including erosion testing, delamination testing, coating integrity testing, heat treat testing, and bend/burst/collapse testing.
Full details can be found in our Hardide-T Mesh Application Note on our website here.